Fujitsu-Siemens Management Blade (FSC BX Blade Servers)
Description
This connector enables hardware monitoring through the Fujitsu-Siemens Management Blade SNMP Agent which supports the Fujitsu-Siemens Blade servers (BX300, BX600, etc.). Needs to run remotely.
Enterprise Connector
This connector requires the Enterprise edition of MetricsHub.
Target
Typical platform: Fujitsu PRIMERGY
Operating system: Out-Of-Band
This connector is not available for the local host (it is applicable to remote hosts only).
Prerequisites
Leverages: Fujitsu-Siemens Management Blade
Technology and protocols: SNMP
Examples
CLI
metricshub HOSTNAME -t oob -c +FujitsuSiemensBlade --snmp v2c --community public
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: oob
connectors: [ +FujitsuSiemensBlade ] # Optional, to load only this connector
protocols:
snmp:
version: v2c # Read documentation for v1, v2c and v3
community: public # or probably something more secure
Connector Activation Criteria
The Fujitsu-Siemens Management Blade (FSC BX Blade Servers) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get on the OID
1.3.6.1.4.1.7244.1.1.1.1.12.1.0must return a value that matches with the3(regular expression)
Metrics
| Type | Collected Metrics | Specific Attributes |
|---|---|---|
| blade | hw.status{hw.type="blade", state="degraded|failed|ok"}hw.status{hw.type="blade", state="present"} | hw.parent.idhw.parent.typeidmodelname |
| enclosure | hw.status{hw.type="enclosure", state="present"} | idmodelnametypevendor |
| fan | hw.fan.speedhw.status{hw.type="fan", state="degraded|failed|ok"}hw.status{hw.type="fan", state="present"} | hw.parent.idhw.parent.typeidnamesensor_location |
| power_supply | hw.status{hw.type="power_supply", state="degraded|failed|ok"}hw.status{hw.type="power_supply", state="present"} | hw.parent.idhw.parent.typeidnamepower_supply_type |
| temperature | hw.status{hw.type="temperature", state="present"}hw.temperaturehw.temperature.limit{limit_type="high.critical"}hw.temperature.limit{limit_type="high.degraded"} | hw.parent.idhw.parent.typeidnamesensor_location |