Dell OpenManage Storage Manager
Description
This connector enables the monitoring for direct attached Dell disk arrays monitoring through the Dell Storage Manager Agent.
Enterprise Connector
This connector requires the Enterprise edition of MetricsHub.
Supersedes
This connector supersedes:
Target
Typical platform: Dell PowerEdge
Operating systems: Microsoft Windows, Linux
Prerequisites
Leverages: Dell OpenManage Server Administrator
Technology and protocols: SNMP
Examples
CLI
metricshub HOSTNAME -t win -c +DellStorageManager --snmp v2c --community public
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: win
connectors: [ +DellStorageManager ] # Optional, to load only this connector
protocols:
snmp:
version: v2c # Read documentation for v1, v2c and v3
community: public # or probably something more secure
Connector Activation Criteria
The Dell OpenManage Storage Manager connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP GetNext on the OID
1.3.6.1.4.1.674.10893.1.20must return a non-empty value
Metrics
| Type | Collected Metrics | Specific Attributes |
|---|---|---|
| battery | hw.status{hw.type="battery", state="degraded|failed|ok"}hw.status{hw.type="battery", state="present"} | hw.parent.idhw.parent.typeidmodelnamevendor |
| disk_controller | hw.status{hw.type="disk_controller", state="degraded|failed|ok"}hw.status{hw.type="disk_controller", state="present"} | controller_numberdriver_versionfirmware_versionhw.parent.typeidmodelname |
| enclosure | hw.status{hw.type="enclosure", state="degraded|failed|ok"}hw.status{hw.type="enclosure", state="present"} | idinfomodelnameserial_numbertypevendor |
| fan | hw.fan.speedhw.status{hw.type="fan", state="degraded|failed|ok"}hw.status{hw.type="fan", state="present"} | hw.parent.idhw.parent.typeidinfoname |
| logical_disk | hw.logical_disk.limithw.status{hw.type="logical_disk", state="degraded|failed|ok"} | hw.parent.idhw.parent.typeidnameraid_level |
| other_device | hw.status{hw.type="other_device", state="degraded|failed|ok"}hw.status{hw.type="other_device", state="present"} | device_typehw.parent.idhw.parent.typeidinfoname |
| physical_disk | hw.physical_disk.sizehw.status{hw.type="physical_disk", state="degraded|failed|ok"}hw.status{hw.type="physical_disk", state="predicted_failure"}hw.status{hw.type="physical_disk", state="present"} | hw.parent.idhw.parent.typeidinfonameserial_numbervendor |
| power_supply | hw.status{hw.type="power_supply", state="degraded|failed|ok"}hw.status{hw.type="power_supply", state="present"} | hw.parent.idhw.parent.typeidinfoname |
| temperature | hw.status{hw.type="temperature", state="degraded|failed|ok"}hw.status{hw.type="temperature", state="present"}hw.temperaturehw.temperature.limit{limit_type="high.critical"}hw.temperature.limit{limit_type="high.degraded"}hw.temperature.limit{limit_type="low.critical"}hw.temperature.limit{limit_type="low.degraded"} | hw.parent.idhw.parent.typeidname |