Skip to main content

HP Insight Management Agent - Drive Array

Description

This connector monitors the HP/Compaq Drive Arrays by connecting to the Storage Management SNMP sub-agent of the HP Insight Manager agent.

hardware hpe linux solaris windows

Enterprise Connector

This connector requires the Enterprise edition of MetricsHub.

Superseded Connector

This connector is superseded by:

Target

Typical platform: HPE ProLiant

Operating systems: Microsoft Windows, Linux, HP OpenVMS, HP Tru64, Out-Of-Band, Oracle Solaris

Prerequisites

Leverages: HP Insight Management Agents

Technology and protocols: SNMP

Examples

CLI

metricshub HOSTNAME -t win -c +CpqDriveArrayNT --snmp v2c --community public

metricshub.yaml

resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: win
connectors: [ +CpqDriveArrayNT ] # Optional, to load only this connector
protocols:
snmp:
version: v2c # Read documentation for v1, v2c and v3
community: public # or probably something more secure

Connector Activation Criteria

The HP Insight Management Agent - Drive Array connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP GetNext on the OID 1.3.6.1.4.1.232.3.2.2.1.1 must return a non-empty value

Metrics

TypeCollected MetricsSpecific Attributes
batteryhw.status{hw.type="battery", state="degraded|failed|ok"}
hw.status{hw.type="battery", state="present"}
hw.parent.id
hw.parent.type
id
model
name
disk_controllerhw.status{hw.type="disk_controller", state="degraded|failed|ok"}
hw.status{hw.type="disk_controller", state="present"}
controller_number
firmware_version
hw.parent.type
id
info
model
name
serial_number
enclosurehw.status{hw.type="enclosure", state="degraded|failed|ok"}
hw.status{hw.type="enclosure", state="present"}
bios_version
id
info
model
name
serial_number
type
vendor
fanhw.status{hw.type="fan", state="degraded|failed|ok"}
hw.status{hw.type="fan", state="present"}
hw.parent.id
hw.parent.type
id
name
sensor_location
logical_diskhw.logical_disk.limit
hw.status{hw.type="logical_disk", state="degraded|failed|ok"}
hw.parent.id
hw.parent.type
id
name
raid_level
physical_diskhw.physical_disk.size
hw.status{hw.type="physical_disk", state="degraded|failed|ok"}
hw.status{hw.type="physical_disk", state="predicted_failure"}
hw.status{hw.type="physical_disk", state="present"}
hw.parent.id
hw.parent.type
id
info
name
serial_number
vendor
power_supplyhw.status{hw.type="power_supply", state="degraded|failed|ok"}
hw.status{hw.type="power_supply", state="present"}
hw.parent.id
hw.parent.type
id
name
power_supply_type
temperaturehw.status{hw.type="temperature", state="degraded|failed|ok"}
hw.status{hw.type="temperature", state="present"}
hw.parent.id
hw.parent.type
id
name
sensor_location