Adaptec - StorMan - RAID
Description
This connector provides information about physical disks and volumes for Adaptec SAS RAID controllers through the arcconf utility.
hardware linux raid solaris storage
This connector requires the Enterprise edition of MetricsHub.
Target
Typical platform: Adaptec
Operating systems: Oracle Solaris, Linux
Prerequisites
Leverages: arcconf
Technology and protocols: Commands
This connector requires advanced privileges on the managed host for the command below:
/[opt|usr]/StorMan/arcconf
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the metricshub account:
metricshub ALL=(root) NOPASSWD: /[opt|usr]/StorMan/arcconf
Examples
CLI
metricshub HOSTNAME -t solaris -c +AdptStorManUnix --ssh -u USER --sudo-command-list /[opt|usr]/StorMan/arcconf
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: solaris
connectors: [ +AdptStorManUnix ] # Optional, to load only this connector
protocols:
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using metricshub-encrypt
useSudo: true
useSudoCommands: [ "/[opt|usr]/StorMan/arcconf" ]
Connector Activation Criteria
The Adaptec - StorMan - RAID connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The device type must be one of: Solaris, SunOS, Linux
- The command below succeeds on the monitored host:
- Command:
/bin/sh ${file::embeddedFile-1} - Output contains:
Hard drive(regex)
- Command:
Metrics
| Type | Collected Metrics | Specific Attributes |
|---|---|---|
| battery | hw.status{hw.type="battery", state="degraded|failed|ok"}hw.status{hw.type="battery", state="present"} | hw.parent.idhw.parent.typeidnametype |
| disk_controller | hw.status{hw.type="disk_controller", state="degraded|failed|ok"}hw.status{hw.type="disk_controller", state="present"} | controller_numberdriver_versionfirmware_versionhw.parent.typeidinfomodelnameserial_number |
| logical_disk | hw.logical_disk.limithw.status{hw.type="logical_disk", state="degraded|failed|ok"} | hw.parent.idhw.parent.typeidnameraid_level |
| physical_disk | hw.physical_disk.sizehw.status{hw.type="physical_disk", state="degraded|failed|ok"}hw.status{hw.type="physical_disk", state="present"} | hw.parent.idhw.parent.typeidinfomodelnameserial_numbervendor |